Descargar Imprimir esta página

Velleman DVM892N Manual Del Usuario página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
9.6 DIODE AND CONTINUITY
range
Overload protection: 700 V DC or AC rms
9.7 BATTERY TEST
range
1.5 V
9 V
Overload protection: F500 mA/1000 V
9.8 TEMPERATURE
range
°C
NiCr-NiSi sensor
Overload protection: F500 mA/1000 V
10. Voltage Measurement
Do not measure circuits that may contain voltages > 700 V
Use extreme caution when measuring voltages higher than 60 VDC
or 30 VAC rms.
Always place your fingers behind the protective edges of the test
probes while measuring!
V. 01 – 30/08/2016
DVM892N
Do not conduct diode or continuity measurements on
description
display reads the
approximate forward
voltage of the diode
built-in buzzer sounds
if resistance < 50 Ω
accuracy
± (5.0 % rdg + 5 digits)
-50 to 150 °C
150 to 800 °C
live circuits
forward DC current ± 1 mA
reversed DC voltage ± 3.0 V
open-circuit voltage ± 3.0 V
load current
100 mA
5 mA
accuracy
± (3 °C + 1 digit)
± (3 % + 1 digit)
11
test condition
resolution
1 mV
10 mV
resolution
1 °C
©Velleman nv

Publicidad

loading

Este manual también es adecuado para:

Ii 700 vIii 600 v