Operation
Dip Switch Interpretation (for AC)
DIP switch
On/Off station
Sw1
Sw2
Sw3
Sw4
Sw5
Sw6
Sw7
Sw8
Difference between the Function of the Master Wired Controller and Slave Wired Controller
Comparison
Master wired
item
controller
All functions
Function
are available
7
Function
On
Slave wired controller
Off
Master wired controller
On
Ambient temp. display on
Off
Ambient temp. display off
On
Collect ambient temp. from PCB of indoor
Off
Collect ambient Temp. from wired controller
On
Non-volatile memory invalid
Off
Non-volatile memory valid
On
Old protocol
Off
Selfadaption
On
reserved
Off
reserved
On
Model with Up/Down and Left/Right swing
Off
Model with Up/Down swing
On
Fresh Air unit
Off
General unit
Slave wired controller
1. ON/OFF, Mode, Fan Speed, Temp. Setting, Swing, Energy Saving,
Clock function, Heat Reclaim Ventilation function, Mode Setting, Screen
Saving and Child Lock are available
2.Cancel the filter cleaning icon
3.Look up the detailed parameter and malfunction code
Default setting
Off
Off
Off
Off
Off
Off
Off
Off