Installation
Preliminary checks
Take the EASYPRESS
out of
®
the packaging and check the
following:
- check for damage,
- check the RATINGS corre-
spond with those required,
- that the cable bushings and
screws are in place,
- that EASYPRESS
's inlets and
®
outlets are clean and free of
any packaging materials,
- that the check valve moves
smoothly.
Hydraulic connections
Orientation
EASYPRESS
can be installed
®
at any angle depending on the
flow direction, as indicated in
the diagrams.
Position
EASYPRESS
can either be fit-
®
ted directly to the pump outlet
or anywhere along the delivery
line. Never install taps between
the pump and EASYPRESS
Do not install a non-return
valve between EASYPRESS
and the taps, meanwhile it is
possible, although not neces-
sary, to install a non-return
valve on the suction piping of
the pump.
NOTE 1 - DRY RUNNING = there is no flow and the pressure is
lower than that of the pump start-up pressure (Pm). It occurs when
there is no water. After 15 seconds EASYPRESS
and indicates an ERROR message. EASYPRESS
tries to resume NORMAL SERVICE at intervals of increasing time
(15, 30, 60 minutes and successively once every hour/optional 24
hours). If EASYPRESS
detects any pressure and/or flow, NORMAL
®
SERVICE is resumed, otherwise, the pump is stopped again until
the next attempt is made. A MANUAL attempt to resume NORMAL
SERVICE can be made at any time.
NOTE 2 - FREQUENT START-UP = the repeated stopping and
starting of the pump at intervals of less than 2 minutes from each
other. This may cause damage to the pump. In the event of leaks
or extended use at excessively low flow rates [less than 2 litres
Red =
Blue =
Yellow =
Electrical connections
The electrical connections
should be made as indicated
in the diagram which can
also be found on the inside
of the circuit cover.
.
®
®
Attention! The cable bushings
and circuit board cover must
be properly assembled and
secured in order to guarantee
IP 65 grade protection of the
electrical components.
stops the pump
®
AUTOMATICALLY
®
Attention
The pressure applied
by the water column
above EASYPRESS
18 m
not exceed that of the pump
11 m
start-up pressure (Pm). If, for
5 m
example, EASYPRESS
stalled at a height 20 metres
below that of the highest tap
in the system, the pressure
detected by EASYPRESS
be approximately 2 bar.
A model with Pm = 2.2 bar
should, therefore, be installed
in order to guarantee that the
pump is started when a tap is
turned on.
Attention
The maximum pressure
produced by the pump must
be at least 1-1.5 bar higher
than the start-up pressu-
re (Pm). If the pressure
produced by the pump is too
low, EASYPRESS
the pump and indicate a 'dry
running' error message.
Nut
Seal
Cable bushing
min (0,5 gpm)], the pump may be started/stopped as often as once
every few seconds, putting the pump at risk of damage.
In this case, after an interval of time that depends on frequency of
start/stop, EASYPRESS
tes, in order to let it cool down, and indicates an ERROR message.
After 30 minutes, the pump is restarted AUTOMATICALLY.
The pump may be restarted MANUALLY any time.
NOTE 3 - BLOCKAGE DUE TO PROLONGED IDLENESS = If the
pump remains idle for extended periods, it may result in jamming
of the mechanical seal or impellers. To avoid this problem,
EASYPRESS
performs a restart, lasting 7 seconds every 24 hours.
®
First start-up
Priming the pump
For instructions on how to
must
prime (fill) the pump, see the
®
pump manual.
Attention
is in-
®
EASYPRESS
check valve: do not use the
EASYPRESS
will
pump for priming.
®
Switching the pump on
The red (Power) LED lights up;
EASYPRESS
that there is no pressure within
the system and
starts the pump
(the green 'Status'
LED lights up).
If, within 15 seconds of starting
up, EASYPRESS
does not detect the
correct priming of
the pump, it stops
will stop
the pump and indicates a 'dry
®
running' error message.
Attention
When the pump is started for
the first time, it may have to be
Motor
Press the START/STOP
Line
button
to restart the
pump and
complete the
priming procedure.
stops the pump for the following 30 minu-
®
is fitted with a
®
's outlet to fill the
®
instantly detects
®
POWER
STATUS
®
POWER
STATUS
run for longer in order
to complete the priming
procedure.