Descargar Imprimir esta página

VITO PRO-POWER VICO50A Manual De Instrucciones página 44

Publicidad

Idiomas disponibles

Idiomas disponibles

FREQUENTLY ASKED QUETIONS/ TROUBLESHOOTING
Question/problem - cause
Cause
The motor does not start or turns slowly:
• No supply voltage;
• The supply voltage is too low;
• The temperature is too low;
• Failure in the pressure switch;
• Failure in the motor;
The compressor runs, but has not enough pressure or
has a low discharge capacity:
• The air filter is clogged;
• There is a leak in the check and safety valve;
• There is a leak in the discharge pipe;
• The seals are damaged;
• The tank drain screw is leaking;
• The cylinder and segments are damaged;
The motor stops suddenly:
• The moving parts are damaged because of the
absence or low oil level in the pump;
• The moving parts are damaged or blocked;
The air compressor stops and the overload relay trips:
• Motor overheating;
• There is blockage or damage to rotating parts,
which causes the motor to overheat;
The compressor runs, the pressure is shown on the
pressure gauge, but the air tools do not function:
• There is a leak in the compressed air hose;
• There is a leak in the quick-release coupling;
• The pressure set in the pressure regulator is too
low;
Excessive oil consumption:
• The oil level is too high;
• The cylinder and segments are damaged;
44
Solution
• Check the plug, socket and circuit breaker of the
power supply circuit;
• Avoid too long extension cords;
Use an extension cord with enough transversal
cross-section;
• Do not operate the compressor with outside
temperatures below +5°C;
• Repair or replace;
• Repair or replace;
• Clean or replace;
• Check and repair the valve;
• Check and repair;
• Replace the damaged seals;
• Tighten the screw by hand;
Check the screw's joint and replace, if necessary;
• Repair or replace;
• Check the condition of moving parts and replace if
necessary;
• Repair or replace damaged parts;
• Let the compressor cool down, reset the overload
relay and switch the compressor back on;
• Remove or replace the parts, press the overload
relay trip button and restart the compressor;
• Check the compressed air hose and tools. Replace
them, if necessary;
• Check quick-release coupling and replace if
necessary;
• Increase the pressure in the air outlet pressure
regulator;
• Check and adjust the oil level;
• Repair or replace;

Publicidad

loading