DC voltage measurement
Range
600,0 mV
6,000 V
60,00 V
600,0 V
1000 V
Input impedance: 10 MΩ
AC+DC voltage measurement
Range
6.000 V
60.00 V
600.0 V
1000 V
Input impedance: 10 MΩ
Frequency range: 45 Hz...400 Hz
Low Z measurement
Range
6.000 V
60.00 V
600.0 V
1000 V
All AC voltage ranges are specified from 5% to 100% of range
Input impedance: 3 kΩ
Frequency range: 45 Hz...400 Hz
Resistance measurement
Range
600,0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
CMM-30 – USER MANUAL
Accuracy
(0.5% m.v. + 8 digits)
(0.8% m.v. + 5 digits)
(1.0% m.v. + 3 digits)
Accuracy
(1.5% m.v. + 20 digits)
(1.5% m.v. + 5 digits)
Accuracy
(3.0% w.m. + 30 digits)
(3.0% w.m. + 5 digits)
Accuracy
(1.5% m.v. + 5 digits)
(2.0% m.v. + 10 digits)