8. Welding the membrane at the fastening points
Proceed with the welding process in accordance with the isoweld
operating instructions.
For an efficient process, we recommend the following procedure:
1. Place at least 10 magnets to the right of the points to be welded (A).
2. Weld the first of these points (B).
3. Place the magnet on to this fastening point within 3 seconds of completing the
welding (C).
4. Proceed to weld the following points 2 to 10 as described in steps 2 and 3 (D).
5. Move the isoweld
(E).
6. Proceed to weld points 11 to 20 of the line on the left, as described in steps 2 to 4.
7. etc.