4.1.2.1.3- Cleaning
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.
The time between cleaning (in hours) can be adjusted depending on the water
hardness of your swimming pool.
It is possible to select cleaning intervals from 1 to 8 hours.
Note: Password "1234" is required to modify this
function.
4.1.2.1.5 Acid / Alkali
With this option you can select the type of pH corrector to be used in your
swimming pool.
Attention: It should be selected correctly otherwise the
dosing system will work opposite to expected.
Acid: Select this mode if you are going to inject pH reducer into the swimming
pool (default mode).
Alkaline: Select this mode if you need to inject pH increaser into the swimming
pool.
Access this option from the "Configuration menu". To change this mode to
another one, press OK and confirm the change of mode by selecting "S" and
then press OK again.
Note: Password "1234" is required to modify this
function.
4.1.2.1.6- pH Alarm
The pH adjustment system will give an alarm and the dosing pump will stop
operating when the pump works continuously for more than 2 hours,
This could occur for the following reasons:
Manual PRO250V2 v.1
39 / 46