Descargar Imprimir esta página

Merik 511M Manual Del Usuario página 23

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION STEP 7
Install the Light
• Press the release tabs on both sides of lens. Gently
rotate lens back and downward until the lens hinge
is in the fully open position. Do not remove the lens.
• Install up to a 100 watt maximum light bulb in the
socket. The light will turn ON and remain lit for
approximately 4-1/2 minutes when power is
connected. Then the light will turn OFF.
• Reverse the procedure to close the lens.
• If the bulb burns out prematurely due to vibration,
replace with a Garage Door Opener bulb.
NOTE: Use only standard light bulbs. The use of
short neck or speciality light bulbs may overheat the
endpanel or light socket.
INSTALLATION STEP 8
Attach the Emergency Release
Rope and Handle
• Thread one end of the rope through the hole in the
top of the red handle so "NOTICE" reads right side
up as shown. Secure with an overhand knot at
least 25 mm from the end of the rope to prevent
slipping.
• Thread the other end of the rope through the hole
in the release arm of the outer trolley.
• Adjust rope length so the handle is 1.8 m above
the floor. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the
cut end with a match or lighter to prevent unraveling.
100 Watt (Max)
Standard Light Bulb
WARNING
• To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
CAUTION
– If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
– NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope
AVERTISSEMENT
knot becomes untied, you could fall.
ATTENTION
Trolley
Rope
23
Release Tab
Lens Hinge
Overhand
Knot
Trolley
Release Arm
Emergency
Release Handle

Publicidad

loading