Descargar Imprimir esta página

Broan ULTRA ZB110HL1 Guia De Instalacion página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 10
Retrofit Installation
11
Install Knockout Plate, Connect Wires and Reinstall Wiring Panel
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
2
Screw from
Parts Bag
Light
• See OPERATION section on page
12 for details.
• MASTER switch turns fan system on
along with humidity control and shuts
them off for cleaning and maintenance
purposes.
• Toggle mode can be used to manually
increase fan operating airflow to certified
rate.
• MASTER switch may be located where
it is not easily accessed for everyday
usage; it may need to be labeled and
located where it can't be turned on
without being seen from fan to comply
with local and national codes.
Attach cable
1
clamps to
Knockout Plate.
Knockout Plate
mounts to inside of
Housing and may
be oriented
as desired.
3
Connect wires
Fan
Screw set
aside in
Step 6
5
LIGHT WITH ON/OFF SWITCH
LIGHT
SWITCH
FAN
MANUAL
ON
FAN
MASTER &
SENSOR/
CONTROL
BLK
LINE
WHT
IN
GRD
SWITCH BOX
LIGHT WITH DIMMER SWITCH
MANUAL
ON
SENSOR/
CONTROL
MASTER
BLK
LINE
WHT
IN
GRD
SWITCH BOX
ZB110HL1 Installation Guide
4
14/2
BLK
BLU
WHT
ORG
RED
BRN
BLK
WHT
BLK
GRD
14/3
14/2
BLK
BLU
WHT
RED
DIMMER
SWITCH
BLU
BLK
WHT
GRD
14/4
6
WHT
LIGHT
SENSOR
CONTROL
BLK
FAN
WHT
UNIT
WHT
LIGHT
ORG
BRN
SENSOR
CONTROL
BLK
FAN
BLK
WHT
UNIT