Descargar Imprimir esta página

Robern PC1630D4T Serie Manual De Instalación

Ocultar thumbs Ver también para PC1630D4T Serie:

Publicidad

Enlaces rápidos

701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
Installation
/ Installation / Instalación
This instruction sheet contains information
on how to install the Profiles framed cabinets.
This series comes in various sizes. Refer to
specific model numbers for dimensions.
Read the specific instruction for how your cabi-
net will be mounted. The cabinets can be sur-
face mounted or recess mounted.
Save these instructions for future use and ref-
erence. An improper installation voids the war-
ranty. Installed cabinets cannot be returned.
If you experience any problems with your cabi-
net, contact your dealer or Robern directly.
WARNING: Magnetic Accessory Tool
Holder can be harmful to pacemaker wearers
and others with medical implants.
Limited Warranty — One Year Term
1
209-1289_A_Profiles Framed Cabinets
2030D4 NON ELEC
2030D6 NON ELEC
Ce feuillet d'instructions contient des informations
sur la façon d'installer les armoires de la Profiles
framed. Cette série est disponible en différentes
tailles. Reportez-vous aux numéros de modèles
spécifiques pour les dimensions.
Lisez les instructions spécifiques pour faire votre
armoire sera monté. Les armoires peuvent être
montés en surface, évidement monté ou.
Conservez ces instructions pour l'utilisation et
la référence future. Un inappropriées annule la
garantie de l'installation. Cabinets installés ne
peuvent être retournés.
Si vous rencontrez des problèmes avec votre cabinet,
contactez votre revendeur ou directement Robern.
AVERTISSEMENT: porte-outil accessoire
magnétique peuvent être nocifs pour les porteurs
de stimulateurs cardiaques et autres implants
médicaux avec.
Garantie limitée - UN AN
800.877.2376
PROFILES FRAMED CABINET
Esta hoja de instrucciones contiene información
sobre cómo instalar los gabinetes de la Profiles
framed. Esta serie viene en varios tamaños.
Consulte el número de modelo específico para las
dimensiones.
Lea las instrucciones específicas de cómo se va a
montar el gabinete. Los armarios se puede montar
la superficie, el recreo montado o montado.
Guarde estas instrucciones para su uso y referencia
futura. Un incorrectas anula la garantía de
instalación. Gabinetes instalados no se pueden
devolver.
Si experimenta algún problema con su gabinete,
póngase en contacto con su distribuidor o Robern
directamente.
herramientas de accesorios pueden ser
perjudiciales para las personas con marcapasos y
otros implantes médicos.
Garantía limitada - un término del año
www.robern.com
2430D4 NON ELEC
PROFILES FRAMED CABINET
PROFILES FRAMED GABINETE
PC1230D4TXXXX, PC1630D4TXXXX,
PC2030D4TXXXX, PC2430D4TXXXX,
PC1240D4TXXXX, PC1640D4TXXXX,
PC2040D4TXXXX, PC2440D4TXXXX,
PC1230D6TXXXX, PC1630D6TXXXX,
PC2030D6TXXXX, PC2430D6TXXXX,
PC1240D6TXXXX, PC1640D6TXXXX,
PC2040D6TXXXX, PC2440D6TXXXX,
2430D6 NON ELEC
ADVERTENCIA: Magnetic Holder
rev. 03/13/18 © 2018 Robern, Inc.

Publicidad

loading

Resumen de contenidos para Robern PC1630D4T Serie

  • Página 1 Si vous rencontrez des problèmes avec votre cabinet, Si experimenta algún problema con su gabinete, net, contact your dealer or Robern directly. contactez votre revendeur ou directement Robern. póngase en contacto con su distribuidor o Robern directamente. WARNING: Magnetic Accessory Tool AVERTISSEMENT: porte-outil accessoire Holder can be harmful to pacemaker wearers magnétique peuvent être nocifs pour les porteurs...
  • Página 2 An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code. SAVE THESE INSTRUCTIONS 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 3 Utiliser le tableau ci-dessous pour apprendre à construire un numéro de modèle d'armoire de Profiles. Ce tableau se rapporte au numéro de modèle pour une armoire Profiles de 24" l x 30" H x 4" P. Consulter le catalogue des prix Robern pour obtenir une liste complète des numéros de modèles. Le numéro de modèle est situé à l’intérieur de votre armoire.
  • Página 4 (2) barre de montage en Z (2) Panel lateral de vidrio (2) barra de montaje en “Z” (12) #10 x 1/2 hélice (3) Top Clip (12) #10 x 1/2 tornillo (3) Top Clip 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 5 D6 = minimum 6“ required or 2X6 construction / D6 = 6” minimum requis ou construction de 2X6 / D6 = 6” (152mm) como mínimo requeridas o construcción 2X6 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 6 Slide the door porte et rangez-la dans un endroit sûr. puerta y guárdela en un lugar seguro. off and store in a safe place. 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 7 NEGRO WHITE 120VAC WHITE NEUTRAL/WHITE BLANC 20A GFI BLANC NEUTRE/BLANC BLANCO BLANCO NEUTRAL/BLANCO GROUND MISE À LA TERRE BAJADA A TIERRA GROUND MISE À LA TERRE BAJADA A TIERRA 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 8 Option 1 / opción 1 Option 2 / opción 2 See page 9 See page 10 Voir page 9 Voir page 10 Vea la página 9 Vea la página 10 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 9 5. Vuelva a instalar la placa de acceso posterior. green. 5. Reinstall rear access plate. 4" MAX 102 mm MAX Ground Suelo White Black Blanc Noir Blanco Negro Field Wire Fil de terrain Alambre Campo 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 10 6. Replace two access screws on outlet shelf. 4" MAX 102 mm MAX Ground Suelo White Black Blanc Noir Blanco Negro Field Wire Fil de terrain Alambre Campo 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 11 (110 mm) (168 mm) Espacement minimum de 16" Cabinet la porte au robinet / Mínimo desde la Puerta 20" Cabinet 9-3/4" 5-3/4" al Grifo (248 mm) (146 mm) 24" Cabinet 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 12 Voir la page 16 pour l’assemblage final Go to page 16 for final assembly Consulte la página 16 para ensamblado final #10 X 2” (51 mm) [SS674] 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 13 Espacement minimum de (110 mm) (168 mm) 16" Cabinet la porte au robinet / Mínimo desde la Puerta 20" Cabinet 9-3/4" 5-3/4" al Grifo (248 mm) (146 mm) 24" Cabinet 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 14 1" (25.4 mm) Minimum / 5/16" minimum / #10 x 2" (8 mm) Mínimo (51 mm) [SS674] 203-1349 7/32" (5.5 mm) SS674 Drill Here / forent ici / taladro aquí 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 15 Aller aux page 16 pour l’assemblage final. Ir a la página 16 para el montaje final. Go to page 16 for final assembly. #10 X 2” (51 mm) [SS674] 8-[SS676] 8-[SS672] 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 16 à l'autre et entrent et sortent puerta frontal de lado a lado y dentro y fuera (vea side to side and in and out (see figure 2B). (voir figure 2B). la figura 2B). 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 17 Cabinet ou des gabinete directamente detrás de la bisagra, ya que cur to cabinet or items. articles. puede provocar daños al gabinete o artículos. [SS134] [SS672] [SS131] (12) [SS131] 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 18 No Ammonia Sans Ammoniac No Ammonia / Sans ammoniac / Sin amoníaco Sin Amoniaco No Vinegar / Sans vinaigre / Sin Vinagre No Vinegar Sans Vinaigre Sin Vinagre 209-1289_A_Profiles Framed Cabinets 800.877.2376 www.robern.com rev. 03/13/18 © 2018 Robern, Inc.
  • Página 19 RO- or workmanship which are reported to ROBERN in d’un (1) an de la date de livraison. ROBERN n’est pas res- BERN por escrito dentro de un (1) año a partir de la fecha writing within one (1) year from the date of delivery.