IMPORTANT SAFETY INFORMATION ABOUT
A LP-gas cylinder for use with this appliance must have a capacity of
and must be equipped with a Type 1 connector and an OPD (overfill protection
device). Figure 1
The LP-gas supply cylinder to be used must be constructed and marked in
accordance with the specification for LP-gas cylinders of the U.S. Department of
Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinder, Sphere and Tubes for the Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and shall
not be used in a building, garage, or any other enclosed space.
When this appliance is not in use, the gas must be turned off at the supply
cylinder.
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children. Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage, or any other enclosed
areas.
The maximum inlet supply pressure, as follows:
"Max. gas supply:6922 in wc (1723Kpa)"
INPUT
Clearances to
combustible surfaces
Propane Regulator
Pressure
Natural Gas Minimum
Inlet Pressure
PROPANE (LP) GAS
Figure 1
SPECIFICATIONS
Sides 60.96 cm / 24 inches
2.74 kpa / 11 in water column
1.74 kpa / 7 in water column
4
15,000 Btu/hr(4.4kW)
Top:182.8cm/72 inches
9 kgs / 20 lbs
.