Descargar Imprimir esta página

LG ASNQ183C2U0 Manual Del Propietário página 18

Ocultar thumbs Ver también para ASNQ183C2U0:

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Forced operation
Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller
sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.
NOTE
If you do not have the remote controller around here, you can start to operate the forced operation.
If you force to close the front panel, some parts may be damaged.
Auto Restart Function
This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
NOTE
This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6
seconds. The unit will beep twice and the lamp will blink 6 times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.
18 Air Conditioner
Operating mode
Indoor FAN Speed
Setting Temperature
ON/OFF Button
Cooling
High
22°C
ON/OFF Button

Publicidad