Velleman DCM120 Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
4.
Close the clamp and read the current value on the LCD display.
Notes
Before measurement, disconnect the test leads from the meter.
An over-range is indicated by OL.
10.4 LPF (LOW PASS FILTER) MEASUREMENT
Do not measure circuits that may contain voltages > 600 V AC or DC
Use extreme caution when measuring voltages higher than 60 VDC
or 30 VAC rms.
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection button to the desired "LPF" position.
3.
Connect the test leads across the source under measurement.
4.
Read the voltage value on the LCD display.
10.5 RESISTANCE MEASUREMENT
Do not conduct resistance measurements on live circuits. Make sure
all capacitors in the circuit are depleted.
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection button to the desired "
3.
Press the SEL function button to select the "" measurement.
4.
Connect the test leads across the source under measurement.
5.
Read the voltage value on the LCD display.
Notes
If the resistance being measured is connected to a circuit, turn off the
power and discharge all capacitors before applying the test probes.
An over-range is indicated by OL.
10.6 DIODE MEASUREMENT
Do not conduct diode measurements on live circuits. Make sure all
capacitors in the circuit are depleted.
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection switch to the desired "
3.
Press the SEL function button to select "
V. 04 – 25/02/2020
DCM120
 " position.
 " position.
" measurement.
12