12.
Mark the location of the second square beam as point P7
on the floor as close as possible to point P1 (Figure
13.
Measure the distance between points P1 and P7
(Figure
).
G 4
14.
If your measurement is greater than the Allowable
Distance Between P1 & P7 for the corresponding
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Distance (D1)
7.5m (25')
9m (30')
15m (50')
Using the Laser
Operating Tips
• Always mark the center of the beam created by the laser.
• Extreme temperature changes may cause movement of
internal parts that can affect accuracy. Check your accuracy
often while working.
• If the laser is ever dropped, check to make sure it is still
calibrated.
• As long as the laser is properly calibrated, the laser is self-
leveling. Each laser is calibrated at the factory to find level as
long as it is positioned on a flat surface within average ± 4°
of level. No manual adjustments are required.
• Use the laser on a smooth, flat, level, surface.
Turning the Laser Off
Slide the Power/Transport Lock switch to the OFF/Locked
position (Figure
) when the laser is not in use. If the switch
A 6
is not placed in the Locked position, the laser will not turn off.
Using the Laser with Accessories
WARNING:
Since accessories other than those offered by
Stanley have not been tested with this laser, use of
such accessories with this laser could be hazardous.
G 4
Allowable Distance Between
P1 & P7
2.2mm (3/32")
2.7mm (7/64")
4.5mm (3/16")
Only use Stanley accessories that are recommended for use
with this model. Accessories that may be suitable for one laser
).
may create a risk of injury when used with another laser.
The bottom of the laser is equipped with 1/4-20 and 5/8-11
female threads (Figure
B
Stanley accessories. Only use Stanley accessories specified
for use with this laser. Follow the directions included with the
accessory.
Recommended accessories for use with this laser are available
at extra cost from your local dealer or authorized service center.
If you need assistance locating any accessory, please contact
your nearest Stanley service center or visit our website: http://
www.2helpU.com.
Using the L Bracket
The L Bracket can be used with the FMHT77596 laser (Figure
). The L Bracket has a 1/4-20 male thread on which to attach
B
the laser, and magnets and a keyhole for hanging the laser
from a wall.
Maintenance
• When the laser is not in use, clean the exterior parts with a
damp cloth, wipe the laser with a soft dry cloth to make sure it
is dry, and then store the laser in the kit box provided.
• Although the laser exterior is solvent resistant, NEVER use
solvents to clean the laser.
• Do not store the laser at temperatures below -20 ˚C (-5 ˚F ) or
above 60 ˚C (140 ˚F).
• To maintain the accuracy of your work, check the laser often
to make sure it is properly calibrated.
• Calibration checks and other maintenance repairs may be
performed by Stanley service centers.
) to accommodate current or future