SM 1619X08870_SPT67W 7/31/14 9:00 AM Page 14
Preventive maintenance
W RNING
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could
cause
recommend that all tool service be performed
by a Skil Factory Service Center or Authorized
Skil Service Station.
TOOL LUBRICATION
Your Skil tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool have
been engineered for many hours of dependable
service. To maintain peak efficiency of the motor,
we recommend every two to six months the
brushes be examined. Only genuine Skil
replacement brushes specially designed for your
tool should be used.
BEARINGS
Bearings which become noisy (due to heavy
load or very abrasive material cutting) should
be replaced at once to avoid overheating or
motor failure.
Cleaning
To avoid accidents always
W RNING
disconnect the tool from
If an extension cord is
W RNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
W RNING
The use of any other accessories not specified in this manual may create a hazard.
* Blade (P/N 2610921689)
* Wrench (P/N 1619X04755)
** Rip Fence (P/N 2610914629)
Maintenance
Service
serious
hazard.
Extension Cords
Accessories
the power supply before cleaning or
performing any maintenance. The tool may
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
Ventilation openings and switch levers must
We
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
C UTION
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
CARE OF BLADES
Blades become dull even from cutting regular
lumber. If you find yourself forcing the saw
forward to cut instead of just guiding it through
the cut, chances are the blade is dull or coated
with wood pitch.
When cleaning gum and wood pitch from
blade, unplug the saw and remove the blade.
Remember, blades are designed to cut, so
handle carefully. Wipe the blade with kerosene
or similar solvent to remove the gum and pitch.
Unless you are experienced in sharpening
blades, we recommend you do not try.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
3-6
18
6-8
18
8-10
18
10-12
16
12-16
14
(*= standard equipment)
(**= optional accessories)
-14-
Certain cleaning agents
and
solvents
damage
Wire Sizes in mm
Cord Length in Meters
50
100 150
15
30
60
16
16
14
0.75 .075 1.5
16
14
12
0.75 1.0 2.5
16
14
12
0.75 1.0 2.5
16
14
12
1.0 2.5 4.0
12
—
—
—
—
—
2
120
2.5
4.0
4.0
—
—