Step 2:
Use keys
and
to enter the desired Temperature Set Point value and press SET. The configuration
wizard has finished. The unit will begin to regulate the temperature.
If this is not the first time you use the wizard, after completing the last step the display will show the
message dFp (default parameters). You may choose between two options:
0: Only changing the parameters which affect the wizard. The other parameters will remain the same.
1: All parameters return to their factory setting except those which have been modified by the wizard.
Important: The wizard will not reactivate. To enter the wizard mode, initiate Stand-by mode by pressing the
wait until the unit completely halts the temperature regulation (the
sequence one after the other,
Stand-by: If the regulation cannot be instantly stopped due to its configuration, a controlled stop process starts and the
To stop the controlled stop process and force the step to Stand-by, press the Stand-by key again for 3 seconds.
Operation
Display messages
4 | AN41504517847601-000101
,
, SET.
Pump down malfunction error (stop), the time configured in parameter C20 has been exceeded.
Only displayed on screen.
Pump down malfunction error (start-up), the time configured in parameter C19 has been exceeded.
Only displayed on screen.
Probe 1/2/3 failure (open circuit, crossed circuit or temperature outside the limits of the probe)
(Equivalent limits in °F).
Only E2 and E3: Damp evaporator probe.
Activates the alarm relay and the audible alarm.
Flashing with temperature: Probe error 1/2/3 in ADAPTIVE mode.
Flashing with CAL: Probe error 1/2/3 during the calibration.
Open door alarm. Only if the door remains open for a longer time than defined in parameter A12.
Activates the alarm relay and the audible alarm.
Maximum temperature in control probe alarm. The temperature value programmed in A1 has been reached.
Activates the alarm relay and the audible alarm.
Minimum temperature in control probe alarm. The temperature value programmed in A2 has been reached.
Activates the alarm relay and the audible alarm.
External alarm activated (by digital input).
Activates the alarm relay and the audible alarm.
Severe external alarm activated (by digital input).
Activates the alarm relay and the audible alarm.
Alarm for defrost completed due to time-out. The time set in d1 has been exceeded.
Activates the alarm relay and the audible alarm.
HACCP alarm. The temperature has reached the value of parameter h1 during a longer period than established in h2.
Activates the alarm relay and the audible alarm.
HACCP alarm due to a power supply failure. The temperature established in h1 has been reached, following a power
supply failure. Activates the alarm relay and the audible alarm.
Indicates that a defrost is being performed.
Only displayed on screen.
indicator will light up permanently) and press the following keys in
key for 3 seconds and
icon flashes.