Descargar Imprimir esta página

Axis P1354-E Guia De Instalacion página 15

Ocultar thumbs Ver también para P1354-E:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95
Control Button
For location of the control button, see Hardware Overview on page 10.
The control button is used for:
Enabling the Focus Assistant. Press and very quickly release the Control button
Resetting the product to factory default settings. See page 24.
Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS
Service. For more information about these services, see the User Manual.
Specifications
Operating Conditions
Products
AXIS P1354-E
AXIS P1357-E
Cold Startup Delay Switch
The housing used in this Axis product features Arctic Temperature Control, which is enabled by
setting the Cold Startup Delay switch to I (ON). When enabled, this function controls when the
camera restarts after a power cut, when temperatures are below 0 °C (32 °F); the camera is first
heated to approximately 0 °C (32 °F) before it initializes. This prevents damage to camera models
that include moving parts.
Power Consumption
Products
AXIS P1354-E
AXIS P1357-E
Temperature
-30 ºC to 50 ºC
(-22 ºF to 122 ºF) with PoE,
down to -40 ºC (-40 ºF) with High PoE
PoE
max 12.95 W
IEEE 802.3af/802.3at Type 1 Class 3
15
AXIS P13-E Series
Humidity
10-100% RH (condensing)
High PoE
max 25.5 W

Publicidad

loading

Este manual también es adecuado para:

P13-e serieP1357-e