TROUBLE
Upon switching on the ironer does
not work.
The roller does not turn and the
ironing plate does not drop.
After adjusting the temperature by
means
of
the
thermostat,
ironing plate does not heat.
N.B.: All checks and any technical work must be carried out by fully competent, qualified personnel.
TROUBLESHOOTING
POSSIBLE CAUSE
Mains power failure.
M a g n e t o t h e r m a l
intervention.
Card protection fuse (F1-F2) blown.
Motor fuse (F3) blown.
Motor thermal feeler activated.
Emergency
devices
(display shows "Err".)
MODELS WITH INVERTER
Inverter fuse (F4) blown.
Inverter protection activated.
Safety thermostat activated.
the
Thermostat
probe
display shows "Er1" for the right,
"Er3" for the left.
Thermostat probe in short circuit:
display shows "Er2" for the right,
"Er4" for the left.
Measured temperature difference
between
right
and
higher than 40°C.
Check if supply terminals are live.
s w i t c h
Check dispersion toward earth.
Replace fuse and check for cause.
Replace fuse and check for cause.
Wait some minutes for the re-
establishment of feeler contact.
activated
Disactivate the emergency device
and press the pedal.
MODELS WITH INVERTER
Replace fuse and check for cause.
Check error message on inverter's
display.
Reset the safety thermostat using
the relative push button.
disconnected:
Check probes connection.
Use properly the whole ironing
left
probes
surface.
REMEDY