CLEANING
WARNING
Electrical Shock Hazard
Keep water and other liquids from entering the inside of the
equipment. Liquid inside the equipment could cause an
electrical shock.
Do not spray the unit or controls with water or cleaning products.
Liquid could contact the electrical components and cause a short
circuit or an electrical shock. Do not use unit if power cord is damaged
or has been modified.
NOTICE: Do not use cleaning products containing aggressive
chemicals, acids, or that contain chlorine.
TROUBLESHOOTING
Problem
No power to the equipment.
Compressor does not run.
Compressor runs, temperature inside
too warm.
SERVICE AND REPAIR
Serviceable parts are available on Vollrath.com.
To avoid serious injury or damage, never attempt to repair the unit or
replace a damaged power cord yourself. Do not send units directly to
The Vollrath Company LLC. Please contact Vollrath Technical Services
for instructions.
When contacting Vollrath Technical Services, please be ready with the
item number, model number (if applicable), serial number, and proof of
purchase showing the date the unit was purchased.
The Vollrath Company, L.L.C. Headquarters
1236 North 18th Street
Sheboygan, Wisconsin
53081-3201 USA
Main Tel: 800-624-2051 or 920-457-4851
Main Fax: 800-752-5620 or 920-459-6573
Canada Customer Service: 800-695-8560
Tech Services: techservicereps@vollrathco.com
www.vollrath.com
Might be Caused By
Faulty outlet.
Circuit breaker tripped.
Compressor in "delay" cycle.
Faulty controller.
Faulty compressor.
Faulty compressor starter or
capacitor.
Ambient temperature too high.
Excessive ice/frost build up on
evaporator.
Faulty controller.
Dirty or faulty condenser fan.
Dirty or faulty evaporator fan.
Vollrath Europe BV
Beneluxbaan 7
5121
AD RIJEN
The Netherlands
+31161870005
©
To maintain the appearance and increase the service life, clean your
equipment daily.
1. Unplug the equipment.
2. Use a damp cloth or sponge dipped in soapy water to clean the
equipment; rinse and dry thoroughly.
3. A high quality non-toxic glass cleaner may be used to clean the glass
components of the unit.
4. Periodically remove the rear panel and clean the coil fins with a stiff
brush.
PREVENTATIVE MAINTENANCE
Have a qualified person clean the condenser coils, evaporator and fans
twice a year or as necessary.
Course of Action
Have a qualified person replace the outlet.
Reset the circuit breaker.
Wait two minutes for compressor to run.
Have a qualified person repair the equipment.
Lower ambient temperature.
Use manual defrost function.
Use manual defrost function.
WARRANTY STATEMENT FOR THE VOLLRATH CO.
L.L.C.
This warranty does not apply to products purchased for personal,
family or household use, and The Vollrath Company LLC does not offer
a written warranty to purchasers for such uses.
The Vollrath Company LLC warrants the products it manufactures or
distributes against defects in materials and workmanship as specifically
described in our full warranty statement. In all cases, the warranty runs
from the date of the end user's original purchase date found on the
receipt. Any damages from improper use, abuse, modification or
damage resulting from improper packaging during return shipment for
warranty repair will not be covered under warranty.
For complete warranty information, product registration and new
product announcement, visit www.vollrath.com.
Vollrath of China
Vollrath Shanghai Trading Limited
23A, Time Square Plaza | 500
Zhang Yang Road
Pudong, Shanghai 200122
Tel: 86-21-50589580
2016 The Vollrath Company L.L.C.
Vollrath de Mexico S. de R.L. de C.V.
Periferico Sur No. 7980 Edificio 4-E
Col. Santa Maria Tequepexpan
45600
Tlaquepaque, Jalisco | Mexico
Tel: (52) 333-133-6767
Tel: (52) 333-133-6769
Fax: (52) 333-133-6768
Part No. 2350087-1 ml
6/27/16