Descargar Imprimir esta página

EAS ELECTRIC EMG11BT Manual De Instrucciones página 45

Calentador de agua a gas de combustión doméstico

Publicidad

Idiomas disponibles

Idiomas disponibles

Finish above mentioned preparation and confirmation before use.
Finish above mentioned preparation and confirmation before use.
Press ON/OFF key on the operation panel, the LED will display the default water outlet temperature of
Press ON/OFF key on the operation panel, the LED will display the default water outlet temperature of
4℃, press the
4℃, press the
ON/OFF key
ON/OFF key
4.2 Ignition And Operation
Ignition: Open the water outlet valve. the unit will start the exhaust device automatically and make a
"frizzle" ignition sound; the LED will display the actual water outlet temperature. When the unit is
running, there will be air in the gas pipe; therefore a single ignition might not work sometimes. In this
case, close the hot water valve immediately and restart the unit after 10-20 seconds.
For the first use or when the unit has not been used for a long time, operate as above
repeatedly unit all the air in the exhaust pipe has been discharged.
Adjustment of water outlet temperture: The preset range of the water outlet temperature is 35℃~65℃.
Every time the Temp Up key is pressed, the set temperature will rise by 1℃, every time the Temp
Down key has been released for 2 seconds, the screen will display the measured water outlet
temperature.
The set water outlet temperature has the memory function. However, in case of power off, the memory
function will be disabled.
Sound prompt function: In normal circumstances, every time the key on the operation panel is pressed,
the key on the operation panel is pressed, the buzzer will make a sound for 0.5 second. When the unit
fails or the 20-minute timing protection ends, the buzzer will give out continunous alarm sounds, the
combustion indicator will flash rapidly and continuously, Press the ON/OFF key, the alarm will
disappear and the screen will be closed, but the power indicator will not go out (green).
Use of multiple line controllers: The priority principle will apply to the use of multiple line controllers,
whichever is stated first will have the priority, while the power indicator of the controller with priority will
flash, the remaining controller with priority will flash, the remaining controllers can be displayed but will
not operate; the display will be that of the one with priority, When the controller with priority shuts down,
the display of the remaining controllers will be closed.
/
/
key to set the hot water outlet temperature.
key to set the hot water outlet temperature.
Outlet water
Outlet water
temperature
temperature
indication
indication
Water flowing
Water flowing
indication
indication
Blower operating
Blower operating
indication
indication
Burning indication
Burning indication
Set temperature
Set temperature
NOTE
18
Temperature increasing key
Temperature increasing key
Temperature decreasing key
Temperature decreasing key
V.1

Publicidad

loading

Este manual también es adecuado para:

Emg11ngEmg13btEmg13ng