7 FOUR-CONDUCTOR BRANCH
CIRCUIT CONNECTION
NOTE: If residence leads are aluminum conductors,
see WARNING in Section 5, Electrical Requirements.
When connecting to a four-conductor branch circuit, if
local codes permit:
A. Free the neutral (white) lead from being restrained
to any other wires. If necessary, cut the neutral
(white) lead and then re-strip it to expose the
proper length of conductor.
B. Attach the appliance grounding lead (green or bare
copper) in accordance with local codes.
C. Connect the oven neutral (white) lead to the branch
circuit neutral (white or gray) in accordance with
local codes, using a wire nut.
D. Connect the oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in ac cor dance with local codes, using
wire nuts.
E. Install proper strain relief clamp.
F. Install junction box cover.
Range conduit
snaps into box
Red
Junction Box Cover
31-2000694 Rev. 2
Installation Instructions
Black
Branch
circuit
Ground
wires
Alternate
knockout
White
8 SLIDE OVEN INTO OPENING
A. Loop (do not tie) a 36" (91 cm) string around the
conduit before the oven is slid into place. This will
keep the conduit from falling behind the oven.
B. Lift oven into the opening. Use removable
wireformed handles on sides to lift unit. Do not lift
unit by handle or conduit. Two people are required
to lift this oven. Carefully push against oven front
frame. Do not push against outside edges.
C. Leave oven a few inches forward of the cabinet
front frame. Do not push the unit all of the way into
the cutout.
D. As you slide the oven back, pull the string so that
the conduit will lie on top of the oven in a natural
loop.
E. When you are sure the conduit is out of the way,
slide the oven ¾ way back into the opening.
Remove the string by pulling on one end of the
loop.
Pull Out
on String
Loop While
Pushing
the Oven Into
the Cabinet