Descargar Imprimir esta página

Glacier bay FS1A0035BNV Guía De Instalación Y Cuidado página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will be
voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for a
detailed drawing showing the location of the parts listed below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The water will not shut off
completely.
The sink drain at the base of
the sink is leaking.
Possible Cause
The bonnet nut is loose.
The O-ring on the cartridge is
dirty or damaged.
The aerator is dirty or mis-fitted.
The cartridge may be clogged.
The locking nut is loose or
cartridge is not positioned
correctly.
The sink surface is rough or
irregular.
Solution
Tighten the bonnet nut.
Clean or replace the O-ring.
Remove the aerator and check for
debris.
Remove the cartridge and check for
debris.
Ensure the aerator is properly
installed.
Remove the handle and cartridge to
check the rubber seat and spring.
Tighten the lock nut.
Clean or replace.
Apply additional silicone sealant to
the beveled side of the drain flange.
Retighten and test for leaks.
6

Publicidad

loading