4. Checks before use:
4.1 Oil filling and checking.
NOTE: The generator is delivered without oil. Do not attempt to start the
generator without adding oil in the engine first!
The generator has to be on a perfectly flat surface and levelled, to avoid an error
in the oil level reading.
Remove the cap (1) and put the oil into the engine through the hole (2), until reach
(without exceeding) the upper limit (MAX) (3) like shown in the figure below.
The estimated amount of oil to reach a correct level is 0.5 Liters.
Use
good
quality
Recommended oil classification must be API "SJ" (USA) or ACEA "A3" (EUROPA)
or more updated (See container specifications).
NOTE: The engine may consume a bit of oil during its running. Therefore,
before each usage, always check oil level and refill if necessary.
NOTE: Never use oils that are old, dirty, in poor condition or without
specifications (grade and quality). Do not mix different types of oils.
four-stroke
engine
37
oil
SAE10W30
or
SAE10W40.