Descargar Imprimir esta página

GENERGY LIMITED 1500i Instrucciones De Uso página 47

Publicidad

Idiomas disponibles

Idiomas disponibles

7.3 Digital control panel.
Central indicator: Correct running.
Turns on after the generator starts and it means the normal running of the 230V
output.
Left indicator: Generator overload.
If the generator is overloaded, the indicator turns on, at the same time turns off the
230V output indicator (in the center). In this case, the generator will keep running,
but the voltage output will be cut off.
In case of overload, follow the steps below:
1. Disconnect the equipment from the generator.
2. Press the RESET button, according to the figure above.
3. Connect other equipment which power consumption is less than the rated
power performed by the generator.
NOTE: The dirt in the air filter reduces the power generator, so always keep
the air filter in good condition.
45

Publicidad

loading