ADVANCED PROGRAMMING (manual)
This type of programming procedure enables the user to manually enter the leaf delays and deceleration points.
Procedure:
Follow points 1 to 10 of the above paragraph "Automatic programming".
Proceed with the following sequence taking into account that, unlike in the case of automatic programming, this requires a sequence of references in
real time.
11-12- When both leafs are closed, M1 is started up automatically in opening.
13- Press S/S when the leafs reach the required offset (in opening). To indicate and confirm recording, motor M1 stops for a few seconds and then
restarts in opening.
14- Press S/S when the leaf with M1 reaches the (required) deceleration zone. To indicate and confirm recording, motor M1 stops for a few seconds and
then restarts in opening.
15-16- When M1 reaches the end stop (or limit switch) on opening, M2 starts up automatically in opening.
17- Press S/S when the leaf with M2 reaches the (required) deceleration zone. To indicate and confirm recording, motor M2 stops for a few seconds and
then restarts in opening.
18- When the two leafs are both in the open position, the pause time memorisation phase is started.
19- Once the required pause interval has elapsed, press the S/S button and motor M2 starts closing.
20- Press S/S when the leafs reach the required offset (in closing). To indicate and confirm recording, motor M2 stops for a few seconds and then
restarts in closing.
21- Press S/S when the leaf with M2 reaches the (required) deceleration zone. To indicate and confirm recording, motor M2 stops for a few seconds and
then restarts in closing.
22- When M2 reaches the end stop, M1 closes.
23- Press S/S when the leaf with M1 reaches the (required) deceleration zone. To indicate and confirm recording, motor M1 stops for a few seconds and
then restarts in closing.
24- Gate completely closed
25- End of programming (the control unit sets automatically to normal operating mode).
- The memorised values remain stored until a new programming cycle is performed.
P3
P3
45
P3
PAUSE
P3
Time
23
24
P3
P3
P3
25
LD3
End