REPLACE THE FUSE
The Troubleshooting section of this manual describes situations in
which the fuse may need to be replaced.
Tools You Will Need
• Small screw driver
• Towel or soft cloth
• 314 20A fuse (Available on Vollrath.com and found at most
hardware stores)
1. Turn off and unplug the induction range.
2. Place a towel or soft cloth on a flat, stable surface.
3. Gently and carefully, lay the induction range, glass-side down, onto
the towel. Locate the fuse cap.
4. Using screwdriver; press down and turn the fuse holder cap to
release it from the range.
5. Remove the fuse from the holder.
6. Insert a replacement fuse into the holder.
7. Re-insert the holder and use the screwdriver to secure the cap into
the range.
8. Ensure the cap holder is locked into place.