The portable air compressor is equipped
with a cord having a grounding wire with
an appropriate grounding plug.
1. The cord set and plug (O) with this
unit contains a grounding pin (P). This
plug MUST be used with a grounded
outlet (Q).
IMPORTANT: The outlet being used must be installed and
grounded in accordance with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as
the grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood,
or if in doubt as to whether the compressor is properly
grounded, have the installation checked by a qualified
electrician.
DANGER: Risk of electrical shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
• Do not modify the plug provided. If it does not fit the
available outlet, a correct outlet should be installed by a
qualified electrician.
• Repairs to the cord set or plug MUST be made by a quali-
fied electrician.

Extension Cords

If an extension cord must be used, be sure it is:
• A 3-wire extension cord that has a 3-blade grounding plug, and
a 3-slot receptacle that will accept the plug on the product
• In good condition
• Plug is not worn
DXCM271_E110922_27 Gal manual_ENG-FRN-SPN_8382_KM_v12.indd 12
• No longer than 50 feet (15.2 m)
O
• 12 gauge (AWG) or larger. (Wire size increases as gauge number
decreases. 10 AWG and 8 AWG may also be used. DO NOT
Q
USE 14 OR 16 AWG.)
NOTICE: The use of an undersized extension cord will cause volt-
P
age to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of
the air hose by attaching another length of hose to its end. Attach
additional lengths of hose as needed. Always use a minimum 3/8"
(9.5 mm) or greater air hose rated at 300 PSI.

Voltage and Circuit Protection

Refer to the Voltage and Minimum Branch Circuit Requirements
under Pump/Motor Specifications.
CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
• Voltage supply to circuit must comply with the National
Electrical Code.
• Circuit is not used to supply any other electrical needs.
• Extension cords comply with specifications.
• Circuit is equipped with a 15 amp circuit breaker or 15 amp
time delay fuse. NOTE: If compressor is connected to a cir-
cuit protected by fuses, use only time delay fuses. Time delay
fuses should be marked "D" in Canada and "T" in the U.S.
If any of the above conditions cannot be met, or if operation of the
compressor repeatedly causes interruption of the power, it may be
necessary to operate it from a 20 Amp circuit. It is not necessary to
change the cord set.
How to Use Your Unit

How to Stop:

Set the Auto/Off switch to "Off (O)".