Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

How to Start

1. Turn the Auto/Off switch to "Auto (-)" and allow tank pressure
to build. Motor will stop when tank pressure reaches "cut-out"
pressure.
2. Turn the regulator knob clockwise to increase pressure.
IMPORTANT: When using regulator and other accessories refer to
the manufacturers instructions.
WARNING: Risk of bursting. If any unusual noise or vibration
is noticed, stop the compressor immediately and have it checked
by a trained service technician.
The compressor is ready for use.
Shut-down
1. Move Auto/Off switch to the "Off (O)" position.
NOTE: If finished using compressor, follow Steps 2 - 6.
2. Turn the regulator knob counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see Draining Air Tank under MAINTENANCE.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and
weaken the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
DXCM271_E110922_27 Gal manual_ENG-FRN-SPN_8382_KM_v12.indd 14
14
11/2/17 10:17 AM

Publicidad

Tabla de contenido
loading

Tabla de contenido