DEVICE INSTALLATION (FIGURE 2)
Decide where you want to mount the device. Never install the UV-C unit after the pH controller, chlorine
dispenser or salt electrolysis system in the swimming pool installation. The best place to install the device
is directly after the filter. See the schematic diagram in the operating instructions. Make sure there is
always water flowing through the device when the lamp is on. Never install the device in direct sunlight.
Install the device in a dry, well-ventilated area. The device can be installed either horizontally or vertically,
provided that the water flow is from bottom to top (see schematic diagram at the beginning of the
instructions for use), with 30 cm of unobstructed space on the side opposite the lamp connection for
future maintenance. At least one metre of unobstructed space must be left on the side with the lamp
connection for convenient future replacement of the lamp (K) without having to disconnect the entire
device.
CAUTION: All connections and couplings must be hand-tight. Do not tighten them with tools.
Otherwise damage may occur.
1. Unscrew the nut (N) from the housing (U). Remove the UV-C lamp (K) from the supplied tube (see
packaging) and carefully slide the lamp into the quartz sleeve (M). Place the lamp (K) with the contact
pins in the lamp fitting (L) and then tighten the nut (N) on the housing (U).
2. Fit the supplied pipe clamps (O). Then insert the unit into the pipe clamps. Tighten the threepiece
coupling (I) firmly, while ensuring the correct position of the sealing rings (P), both at the connections
and the quartz sleeve (see figure 2).
3. Mount the unit in the circuit by means of the three-piece coupling (I) and the glue coupling for the
flow switch (V *For amalgam only). The glue connections of the three-piece coupling are Ø63 mm or
2". If the pipes are smaller than Ø63 mm or 2", use the Ø63 x 50 mm (T) or 2" x 1.5" x 1" adapter. This can
be glued in the three-piece coupling (I) and in the glue coupling for the flow switch (V *For amalgam
only). The inside of the adapter (T) has internal screw threads at one end, making it possible to fit a
hose tail adapter (not included) with sealing ring. ATTENTION: Allow the glued parts to evaporate for
8 hours.
4. Insert the plug of the UV-C device into an earthed wall socket that is protected by a residual current
device.
5. Look through the transparent parts of the device to make sure the lamp is lit.
6. The device is shut off when power is disconnected from the device.
*For amalgam only
7.
The glue coupling for the flow switch (V) must be positioned on the three-piece coupling (I) with
the screw thread (W) facing up (see figure 2). The glue coupling (V) can be glued to a three-piece
coupling (I). Mount the flow switch (X) which is attached to the electrical section (S) directly to the
screw thread (U) of the glue coupling (V) (see figure 2). If the flow switch is mounted differently, the
device will not work. The arrow on top of the flow switch (X) must always point in the direction of
water flow. If it points in the direction opposite the water flow, the UV-C device will remain off.
8. When no water is flowing through the device, the flow switch automatically switches the unit off.
UV-C and Pool equipment
UV-C and Pool equipment
TIMER UV-C |
9
EN

Publicidad

loading

Este manual también es adecuado para:

Timer uv-c 75wTimer uv-c 40w130w amalgam75w amalgam40w amalgam