Installation Procedure - Toto DuoFit WT171M Manual De Instrucciones

Ocultar thumbs Ver también para DuoFit WT171M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION PROCEDURE

Installing the In-Wall Tank System
Loosen the bolts on the adjustable
legs and place the carrier into the
wood frame.
Adjust the carrier to the desired
height with reference to the
Finished Floor (see Table 1 for
guide) and marked on the wood
frame.
Tighten the two bolts on the legs
to secure the height of the carrier.
Mark the location for drilling pilot
holes for the screws to secure
the carrier to the wood frame.
There are six (6) screws for the
A
side (3 on each side) and two on
the feet. Make sure the carrier
is flush with the wood frame
before placing the markings.
A
Remove the carrier from the
wood frame, drill six (6) 1/8"(3mm)
A
holes on the wall stud (Trimmer/
Jack) and two (2) on the subfloor
(plywood); for concrete, drill 3/8"
(10mm) holes for anchors.
For vertical drain installation, clip the upper
bracket to the front slot of the frame as shown.
Drill a 3-3/4"(95mm) hole on the subfloor 1-3/4"
(45mm) from the front of studs.
1-¾"
Front Slot
( 45 )
H
A
A
Ø 1/8" [3mm]
1
2
A
B
A
2
Ø 1/8"
[3mm]
1
B
B
For left or right drain installa-
tion, clip the upper bracket to
the back slot of the frame as
shown.
45°
45°
Back Slot
4
Use the lower bracket to lock the outlet pipe to the Carrier.
Place the carrier into the wood frame, make sure the carrier is horizontally leveled
and fl ush is placed in the front face of the stud frame.
Use the screws provided for securing the System. Install the outlet pipe to the
sewer pipe.
H
Plumb the water supply line and check for
leak. Do not remove the block cap of the
inlet for Washlet.
CAUTION
This indicates that misoperation could
result in injury or physical damage.
It is important to reconfirm
that there is no water
leakage at all connections.
Required
Incomplete connection
could cause foul odor or
water to leak.
The
symbol indicates something that
must be done.
Insert the mud guard for the inlet and outlet, the push plate
rough-in for the push plate and the two (2) Threaded
Mounting Stud for the mounting bowl on the inner holes.
1
1
1
1
2
2
Before connecting the flexible hose
to the fill valve, open shutoff valve
to let water run for a minute or two.
After that, shut off the valve and the
main supply valve.
5

Publicidad