Descargar Imprimir esta página

Mi-T-M MH-0070-0M10 Manual Del Operador página 17

Publicidad

Idiomas disponibles

Idiomas disponibles

PUMP PRESSURE ADJUSTMENT:
While heater is operating, turn relief valve clockwise to increase, counterclockwise to decrease. Use flat
blade screwdriver to turn valve. Correct pump pressure is as follows:
For best measurement of pressure, test with full tank of fuel. Optimum pressure occurs when the nose
cone is cherry red and there are no extending flames from the heater.
Adjusting Screw
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
CONTROL PCB
POWER LAMP
(LED)
THERMOSTAT
(TEMP.CONTROL)
BLACK
PHOTO CELL
BLACK
POWER
SWITCH
POWER
PLUG
BLACK
AC 120V
WHITE
60Hz
GREEN
EARTH
MH-0070-0M10
Kerosene Portable Heaters Manual
Model #
MH-0070-0M10
MH-0125-0M10
MH-0175-0M10
MH-0215-0M10
Tolerance ± 10%
BLACK
Red
CN4
IGNITOR
Red
BLACK
MOTOR01
PUMP
MOTOR
BLUE
MOTOR02
GREEN
ACN2
EARTH
CN2
CN3
CD5
R-TH
BLUE
ROOM
SENSOR
BLUE
LIMIT
FUSE
CONTROL
8A/125VAC
BLACK
ACN1
BLACK
MAINTENANCE
Pump Pressure
4.0 PSI
5.0 PSI
7.5 PSI
9.0 PSI
SPARKPLUG
BLUE
RED
CAPACITOR
12uF/250VAC
POWER
PLUG
AC 120V
60Hz
EARTH
MH-0125-0M10, MH-0175-0M10, MH-0215-0M10
CONTROL PCB
POWER LAMP
MOTOR01
(LED)
MOTOR02
THERMOSTAT
(TEMP.CONTROL)
ACN2
CN3
CD5
CN2
R-TH
BLACK
BLUE
ROOM
PHOTO CELL
BLACK
SENSOR
BLUE
POWER
LIMIT
FUSE
SWITCH
CONTROL
8A/125VAC
BLACK
ACN1
BLACK
BLACK
WHITE
GREEN
BLACK
SPARKPLUG
BLUE
CN4
IGNITOR
BLUE
BLACK
BLUE
PUMP
MOTOR
BLUE
RED
CAPACITOR
30uF/250VAC
GREEN
EARTH
17

Publicidad

loading

Este manual también es adecuado para:

Mh-0125-0m10Mh-0175-0m10Mh-0215-0m10