Care and Cleaning
Remove cartridge and clean valve body in household vinegar to remove corrosive mineral build up. Rinse
under running hot water to ensure valve is free of foreign debris.
Trouble Shooting Chart
Problem
Water flow is less than normal.
Water continues to run colder than
original temperature setting.
Valve is leaking around the cap
retaining nut area.
Tempered hot water temperature is
not hot enough.
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to
cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Symmons Industries, Inc.
Copyright © 2022 Symmons Industries, Inc.
Cause
Screen in cartridge is dirty or
clogged.
Check valve is not completely
sealed allowing cold water to mix
with hot.
Water leaking from o-ring seal.
Hot water supply into valve is not
10°F (5.55°C) above desired set
point temperature. Temperature
setting it to low.
31 Brooks Drive
Braintree, MA 02184
www.symmons.com
1) Remove cartridge and clean un-
2) Remove cartridge and clean in
household vinegar or replace by
ordering cartridge replacement kit.
Remove screen/check valve and
clean under running water.
Replace cartridge by ordering
cartridge replacement kit.
Increase hot water supply
temperature into valve. Reset
temperature according to "Setting
valve temperature" instructions.
Phone: (800) 796-6667
gethelp@symmons.com
ZV-3425 REV D
Solution
der running water.
Fax: (800) 961-9621
031522