Inserting the device

Place device on sealing frame and slide forwards as far as it
will go (sealing frame must slide into groove and engage).
Remove the protective film.
Route the power supply cable to the connection point
(extend the cable with however many Wago terminals you
need if necessary).
6

Fixing the unit in place

Screw the two brackets (marked with an arrow pointing in the
vehicle's direction of travel) to the unit using the 4 M6 x 70
screws (with sealant) included in the scope of supply (tighten-
ing torque).
Torque 1.8 Nm
M6 screws must be used for roof thicknesses of more than
50 mm (length = roof thickness + 30 mm) and tensile strength
of 8.8. The screws must be coated with low-strength sealant
(e.g. Loctite).

Installing roof thickness adapters

Base ring (1) and dependent upon the roof thickness, slide
the roof thickness adapters (2 or 2 + 3, included in scope of
delivery) for roof thickness of 25 to 50 mm as far as possible
into the air distributor. Use additional 10 mm roof thickness
adapters (see accessories) if the roof is thicker. Maximum roof
thickness 110 mm.
3
2
1
1,8 Nm
25
30 mm = 1
31 – 40 mm = 1+2
41 – 50 mm = 1+2+3