STEP 3 Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the "Electrical
requirements" section on page 17.
3-wire system
A
B
C
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. 3/4" (1.9 cm) UL-listed strain relief
Untitled-14 23
1. Loosen or remove the screws from the
2. Connect the neutral wire (white or
3. Connect the other wires to outer
D
4. Tighten the strain relief screws.
L1
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system
• Ring-type terminals are recommended.
• Before Installing the Dryer, confirm
center terminal block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
240 V is present between L1 and L2 at
the power receptacle. If the Voltage is
low, it may not dry properly. Review
the "Electrical requirements" section on
page 17 if needed.
English 23
2020-06-22
3:16:06