5. START UP INSTRUCTIONS
5.1. LIST OF MATERIALS
The machine includes the following elements that you
will find in the box:
• Pump.
• Adaptor.
• Instruction manual.
Remove all elements from the box and check that all
are included.
Remove carefully all the elements from the box
and make sure that all listed parts are included. Due
to the quality controls done at the factory it is highly
improbable that your machine has any faulty part
or that any elements are missing. If you find any
damaged part or there are any elements missing,
do not use the machine until the problem has been
solved or you have been given the missing parts.
Usage of the machine with defective or missing parts
is dangerous and could result in personal injuries.
5.2. MOUNTING AND INSTALLATION
This machine comes mounted and ready for use. No
mounting is necessary except for the coupling of the
impulsion hose, height adjustment of the buoy and
connecting the pump to the mains.
5.2.1. INSTALLATION OF THE IMPULSION HOSE
Connect the hose to the water exit of the pump.
This hose has an exit adaptor that allows different
sizes of hose to be fitted to the pump.
- Zone A: 32 mm hose connections using O ring.
- Zone B: 25 mm hose connections using O ring.
mediante abrazadera.
- Zone C: Connection of 1¨ adaptors. In this case,
you will have to cut the adaptor on the dotted line
between B and C using a saw.
- Zone D: If you remove the adaptor you can fit a
1.5¨ adaptor.
5.2.2. ADJUSTMENT OF THE BUOY
This pump has a float that automatically starts and
stops the pump based on the amount of water around
the pump. When the buoy is in the air in a vertical
downward position (1) the pump stops. When the
buoy floats in the water (2) the pump works.
1
22/88
B
C
A
D
2