POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
NOTICE:
Do not overload the generator's capacity. Exceeding the
generator's wattage/amperage capacity may damage the
generator and/or electrical devices connected to it.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .......... 420cc OHV, Air Cooled Overhead Valve
Replacement Spark Plug ................ NGK BP6ES, LG F7TC,
Lubricant Fill Volume .................................... approx. 32 oz.
Fuel Volume ................................................................ 6 gal.
*Rated running watts determined by PGMA Standard G300
ELECTRICAL
Application/Equipment
Emergency / Home Standby
Clock Radio
Lights (qty. 4 x 75 W)
Refrigerator
Furnace Fan
Water Well Pump
Microwave
Sump Pump
Electric Range (per element)
Job Site
Electric Drill − 1/2 HP
Airless Sprayer − 1/3 HP
Quartz Halogen Work Light
Reciprocating Saw
Air Compressor − 1 HP
Circular Saw − 7-1/4 in.
Planer/Jointer − 6 in
Miter Saw − 10 in.
Table Saw/Radial Arm Saw − 10 in.
*Wattages listed are approximate. Check tool or appliance for actual wattage.
FEATURES
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ..................................................... 45.8A/22.9A
or equivalent
Rated Output*.........................................................5,500 W
Rated Starting Watts ..............................................6,875 W
Rated Frequency ........................................................60 Hz
Page 10 — English
Estimated
Estimated
Running
Starting
Watts*
Watts*
50
0
300
0
700
2200
800
2350
1000
2200
1000
0
1050
2200
2100
0
600
900
600
1200
1000
0
960
960
1600
4500
1400
2300
1800
1800
1800
1800
2000
2000