INSTALLATION
Wiring Connections
IN-LINE / REMOTE BLOWER WIRING
Remove the top cover of the electrical box by extracting
1
the two screws. Refer to the illustration.
Remove one of the round knockouts using a flat blade
2
screwdriver.
The terminal block is wired for an internal blower. For
3
in-line and remote blowers, the existing blue and brown
wires must be removed and placed in the two left posi-
tions to accommodate the in-line or remote blower wire.
Refer to the illustration.
Insert Romex
®
wire from the in-line or remote blower
4
through the knockout and secure using an approved
cord stain relief.
Connect white to blue, black to brown and green to the
5
ground screw. Refer to the illustration.
Verify all wires are secure and not pinched between the
6
cover, and install the cover.
All manuals and user guides at all-guides.com
MOVE
WIRES HERE
Wiring location
GROUND
TO IN-LINE/REMOTE
BLOWER
In-line/remote blower wiring
wolfappliance.com | 9