Assembly:
Very important when connecting the wire rope to
the bottom hook the cable must run on the outside
of the lower limit bar. If ran on the inside of the bar
damage will happen to the wire rope and the hoist.
Mounting
Ensure the hoist is mounted on a straight bar that allows only for front-to-back swinging, not
left-to-right or rotational swinging. Failure to do so could result in uneven winding of rope onto
the drum, rope jamming and rope damage. When hanging the hoist, ensure it is free from other
obstructions. Always keep the hoist as level as possible to prevent uneven winding.
NOTE:
Always lock the hanger before every lift.
Connecting the Cords
Power cord:
1) Align the power cord with the matching socket on the power
receptacle of the hoist. Tighten the locking ring clockwise.
2) Secure the power cord with the strain relief clip. This clip is
attached to the power cord and secures to a ring on the hoist to
reduce cable strain. Do not allow the power cord to come into
contact with the wire rope or drum.
3) The power cord is designed for distances of 65 ft or less. For
additional length, use a power cable of 12 (AWG) to prevent a
drop in voltage.
Power cord length selections
Section 14 (AWG) - Cord Length 65 ft.
Section 12 (AWG) - Cord Length 114 ft.
NOTE:
The power cord and control cord are different plug types and cannot be interchanged.