Switch cord connection:
1) Align the control cord with the matching socket on the power receptacle of the
hoist. Tighten the locking ring clockwise.
2) Secure the control cord with the strain relief clip. This clip is attached to the
control cord and secures to a ring on the hoist to reduce cable strain. Do not allow
the power cord to come into contact with the wire rope or drum.
Grounding:
To prevent the risk of electric shock, the power plug must
be plugged into a matching outlet in good condition.
Working Methods
Preparation
• Confirm a safe working environment prior to operation.
• Ensure a minimum of five (5) wraps of wire rope is wound around the drum.
• Discard wire rope that shows signs of excessive wear or broken wires. Look for
corrosion or other defects.
• Connect the main power source. There will be a loss of power if input voltage falls
out of rated voltage by +10%.
• Do not lift loads exceeding the rated load.
Up-and-Down Switching
Press the up button and the drum will take in cable, lifting the load. Press the down button
and the drum will let out cable, lowering the load. To stop the drum, release the button. In
case of emergency, push the red button to stop operation of the hoist.
EN pg.7