GB
CPM 160-8-2 W-oilfree
1.5
Components
01
Compressor unit
02
Intake filter
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
13
Pressure gauge (working pressure)
14
Electric motor
15
External protective motor switch
18
Pressure reducer
19
Quick-action coupling (clean, regu-
lated compressed air)
1.6
Maintenance
1.6.1 Cleaning the intake filter
1. Pull out the filter insert. (Fig. 5a)
2. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
3. Insert the filter insert.
1.7
Compressor inspections
Special inspections are not required for this
compressor.
We recommend that a "qualified person" per-
form a pressure test on the vessel after 10
years, depending on general levels of wear
and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
I/4
The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.
1.8
EC Declaration of Con-
formity
Compressor
CPM 160-8-2 W-oilfree
Year of CE mark: 2009
We declare under sole responsibility that this
product complies with the following direc-
tives and standards:
98/37/EC (up to 28.12.2009); 2006/42/EC
(from 29.12.2009); 97/23/EC (module A);
87/404/EEC;
2000/14/EC;
2006/95/EC; DIN EN ISO 3744 / 12100; DIN
EN 1012 / 60204-1 / 55014-1 / 286-1, EN
61000-3-2, -3-3, -3-11.
pp Marco Lodni
Head of Development/Testing
01.2009
Schneider Druckluft GmbH
Ferdinand-Lassalle-Str. 43
72770 Reutlingen
Machine design: piston compressor
Sound power level L
ISO (RL 2000/14/EC):
Measured value: 93 dB(A),
Guaranteed value: 94 dB(A).
Nominated centre for the conformity evalua-
tion procedure: 0036
Serial no.
T100087
2004/108/EC;
according to DIN EN
WA