Descargar Imprimir esta página

Schneider Airsystems CPM 160-8-2 W-oilfree Manual De Instrucciones Original página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
Table of contents - Part 1
1.1
General information ..................
1.2
Scope of delivery ......................
1.3
Conventional use ......................
1.4
Technical data ..........................
1.5
Components.............................
1.6
Maintenance.............................
1.7
Compressor inspections .............
1.8
EC Declaration of Conformity ......
The specified illustrations appear at the be-
ginning of the Operating Instructions.
1.1
General information
Observe the safety instructions!
Read the Instruction Manual!
1.4
Technical data
Suction capacity
Filling capacity
Voltage
Electric protection, delayed-action
Motor output
Max. operating speed
Compression final pressure
Switch-on pressure
Vessel capacity
Maximum permissible working overpressure of vessel
L
Sound power level according to DIN EN ISO 3744 (RL 2000/
WA
14/EC)
L
Sound pressure level at distance of 4 m
PA4
Overall dimensions: width x depth x height
Weight
Max. number of switching cycles
Operation/Downtime ratio
Min. distance to wall
Ambient temperature
Note: Read and memorise part 2 of the in-
struction manual!
3
Subject to technical modifications. Illustra-
tions may deviate from the original.
3
3
1.2
Scope of delivery
3
– Compressor with instruction manual
4
– Documents accompanying compressed air
4
vessel
4
1.3
Conventional use
4
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
CPM 160-8-2 W-oilfree
160 l/min
70 l/min
230 V
10 A
1,1 kW
2850 rpm
8 bar
6 bar
2 l
9 bar
94 dB(A)
74 dB(A)
330x 250 x 420 mm
11 kg
10 1/h
60:40 --
40 cm
5-35 °C
GB
I/3

Publicidad

loading

Este manual también es adecuado para:

A 222 002