1. To Add / Delete the WatchIN DT
1. From the installer menu enter the Add/Delete menu: Quick Key [7][1][9][5] for BUS
Zones detectors.
2. Use the
/
Zone ID number for which you want to assign (or delete) a detector.
Note:
Make sure that the detector's physical ID number is identical to the ID number you select during programming.
3. Place the cursor on the TYPE field and use the
the WatchIN DT detector.
4. Press
/
5. Repeat the process for the other BUS detectors.
2. Assigning the WatchIN DT to a Zone
1. From the main installer menu enter Zones: One by One option (Quick key [2][1])
2. Select the zone number that you want to assign the BUS detector.
Note:
If you have defined a BUS Zone Expander, select a zone number from the virtual zones (defined by the BUS
zone expander).
3. Define Partitions, Groups, Zone Type and Zone Sound.
4. In the Termination category select [5] BUS Zone followed by
The following display appears:
Z:001
LINK TO:
ID:01
TYPE=IDT25
5. Select the BUS zone number to assign to the programmed zone. The type field will be
updated automatically when selecting the zone.
6. Press
/
and the following display appears:
Z:001
Z:001
RESPONSE:
RESPONSE:
N/A-BUS ZONE
N/A-BUS ZONE
7. Press
/
Configuring the WatchIN DT Parameters
1. To access the WatchIN settings option press [2][0][3] from the main installer menu.
The following display appears:
B- ZONE PRMS:
-
ZONE#=001
(0:01)
2. Select the zone that the BUS zone was assigned to and press
can now program the WatchIN parameters as follows:
Zones Miscellaneous: BUS Zone
Quick Keys
Parameter
[2][0][3][zzz]
LEDS
[1]
Defines the LEDS operation mode
[2][0][3][zzz]
Off
[1][1]
Disables the LEDS operation
All manuals and user guides at all-guides.com
or
/
keys to position the cursor over the BUS
to confirm.
. The loop response category is not applicable to a BUS zone
, assign label and press
WatchIN Installation Manual
/
key to select IDT25 for
/
/
.
/
Default
3 LEDS
.
. You
17