Marmitek AWM2 Modo De Empleo página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
The AWM2 supports two way Marmitek X-10 communication.
Both normal switches (on-off) and Momentary switches can be
connected to the module. These are automatically recognized by
the AWM2.
This module is suitable for installing two-way switches without
wiring between the switches (MicroModules pass on their status
to other MicroModules).
The AWM2 can control Macro's/Scenario's by operating a
conventional switch (with for instance Marmitek ActiveHome).
The inputs are suitable for potential free switches (< +5 Volt in
relation to zero).
The internal appliance module remembers its status after a main
voltage cut-off.
Colour code wire connections
WARNING: THE WIRES OF THE MICROMOdULE CARRY THE LIFE
dANGER 230V MAIN- VOLTAGE!! ALWAYS SWITCH OFF THE MAIN
MASTER SWITCH BEFORE INSTALLING THE MICROMOdULE.
description of the Marmitek MicroModule wires
Blue: common ("0") wire (is internal directly connected to the
neutral clamp (N).)
Brown: input 1, programmed base address + control of the
built-in appliance module
The built-in appliance module will switch from ON to OFF or vise
versa when the brown wire is connected with the blue wire. At
the same time the programmed address will transmit the new
status of the appliance module through the power line. due to this
Marmitek X-10 transmission you are able to switch other Marmitek
X-10 modules (set to the same address). The new status will also
be recognized by other MicroModuls or e.g. the computer interface
(activating macro's, status indication and more).
AWM2™
7

Publicidad

Tabla de contenido
loading

Tabla de contenido