Descargar Imprimir esta página

Kenwood XXV-02A Manual De Instrucciones página 6

Amplificador de potencia de 4/3/2 canales

Publicidad

Idiomas disponibles

Idiomas disponibles

Amplifier Control System
Display mode
You can set up the display items as follows:
1
Enter Menu mode
Press the [MENU] button.
"VOLT"/"CURR"/"TEMP"/"FAN" is displayed.
2
Select a display item
Press the [2] or [3] button.
The display items are switched in the following sequence.
Display
Information
"VOLT"
Indicates the source voltage (V).
"CURR"
Indicates the current consumption (A).
"TEMP"
Indicates the internal temperature (°F/°C).
"FAN"
Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF".
3
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is
displayed.
Separate Amp Control
The following explains how to control the sound of amplifier B using the
Amplifier Control of the unit.
1
Enter Menu mode
Press the [MENU] button.
2
Select the Menu item
Press the [MENU] button.
The setup items are displayed approximately 1 second first, then the set
values are displayed.
3
Adjust the Menu item
Press the [2] or [3] button.
The setup items and set values are switched as follows.
Display
Range
Adjustment Item
"VOLT"/"CURR"/"TEMP"/"FAN"
For the operation method refer to <Display mode>
"BASS"
60/80/100/200 (Hz)
Bass Center Frequency
"BA G"
B–15 — B+15 (dB)
Bass level
"BA Q"
Q1.00/Q1.25/Q1.50/Q2.00
Bass Q Factor
"EXT"
ON/OFF
When the bass extend is set to ON, low frequency response is
extended by 20%.
"TREB"
10/12/15/17 (kHz)
Treble Center Frequency
"TR G"
T–15 — T+15 (dB)
Treble level
"VOL"
–20 — 0 (dB)
Volume offset
"TEMP"
FAHR (Fahrenheit) or
The Fahrenheit or Centigrade temperature unit can be selected
CELS (Centigrade)
for the Display mode.
"DEFA"
For the operation method refer to <Default>
"AMP"
0 — 7
The ID Number you have assigned is displayed.
6
English
FAN
VOLT
TEMP
CURR
100
150
100
2
70
150
70
3
4
50
200
50
200
(MIN)5
LPF
HPF
FREQUENCY(Hz)
FREQUENCY(Hz)
SENSITIVITY(V)
B ch
HPF OPERATION
LPF OPERATION
FILTER
AMP CONT
0
0
200 Hz
150 Hz
HPF
ON
-4
-4
100 Hz
-8
-8
70 Hz
50 Hz
-12
-12
OFF
-16
-16
-20
-20
LPF
OFF
30
50 100 200 400 1K (Hz)
30
50 100 200 400 1K (Hz)
4
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When you hold down the [3] button 3 or more seconds during ID number
display ("AMP"), message "MEMO" is displayed and you can register the values
you have set with the Amplifier Control. To call the Amplifier Control's values,
hold down the [2] button 3 or more seconds during ID number display
("AMP"). Then, you can recall the value when message "LOAD" is displayed.
Default
Resets all values you have set to the initial (default) values.
1
Enter Menu mode
Press the [MENU] button.
2
Select Default mode
Press the [MENU] button.
Select the "DEFA" display.
3
Resets the value to its default
Press the [3] button for at least 2 seconds.
Message "----" is displayed, and the value is initialized.
4
Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
Volume offset value can not be initialized.
Display Demonstration
The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.
Press the [MENU] button for at least 2 seconds.
The indicator flashes in the Demonstration mode.
Canceling the Demonstration mode
Press any button to cancel the Demonstration mode.
Indicator
MENU
2 / 3
100
1
1
2
70
150
0.5
0.5
3
0.3
0.3
4
0.2(MAX)
50
200
(MIN)5
0.2(MAX)
INPUT
HPF
INPUT
FREQUENCY(Hz)
SENSITIVITY(V)
A ch
ISF
OPERATION
HPF
OPERATION
ON
MONO(Lch)
ON
MONO(Lch)
OFF
STEREO
OFF
STEREO

Publicidad

loading