Condition
1:
Applicator
will
not
heat
Thoubleshooting (continued)
Important:
Applicator must
be cooled
to room temperature
for
step
14.
14.
Check
continuity of
the
thermistor. First,
disconnect the
thermistor
lead
from terminal number
1
of
the upper
terminal block (TB2)
(see
Figure
S).
Using
an
ohmmeter,
measure
between the
disconnected
thermistor
lead and
terminal
number 2
of terminal
block TB2
(see
Figure
S).
Important:
Thermistor
lead
must
be disconnected
for this
test.
Measured value between the disconnected
thermistor
lead
and
terminal
number
2
should
be
between .65 and
1.25
Mega-ohms.
If
measured value
is not within this
range, replace the
defective
thermistor
assembly
by ordering Thermistor
Kit
#62-9
680-97
36-0.
If
measured value
is within
the acceptable range, reconnect the
previously
disconnected
thermistor
lead
to terminal number
I
of
terminal block TB2
(see
Figure
S)
and
proceed
to
the
next
step.
15. Check the
power cord for obvious wire
damage.
If
damage
is
observed, replace the
power
cord
by ordering
Power Card
kit
#
62-9680-9924-2(UK).
If
no
damage
is
observed, check the
electrical continuity of
the
power cord wires
(steps
15a
and
15b).
a.
Using
an
ohmmeter, check
for continuity
between
terminal
number
1
(brown wire from cord)
on the
lower terminal
block TB1
and the
AC line terminal
on the
applicator plug
(see
Figures
T
and
U).
o