Shaking the main filter

Figure 7
1
Main filter operating knob
Depending on the quantity of dust cleaned up, shake the main
filter by means of the knob (1).
WARNING!
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.

Emergency stopping

Turn the main switch to "0" position.

Emptying the container

WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Before emptying the container it is advisable to clean the filter
(see "Shaking the filter" paragraph).
Figure 8
1
Dust container
Normal version
Release the container (1), then remove and empty it.
Make sure that the gasket is in perfect condition and
correctly positioned.
Place the container back in position and use the lever to
secure it again.
Version for vacuuming liquids
Make sure that the vacuum cleaner is equipped with a
liquid level sensor and is suitable for vacuum liquids.
Do not vacuum flammable liquids.
If foam forms, turn off the vacuum cleaner immediately
and empty the container. The filter element will be wet
after liquids have been vacuumed. A wet filter element
can quickly become clogged if the vacuum cleaner is
then used to vacuum dry substances. For this reason,
make sure that the filter element is dry or replace it with
another one before using the vacuum cleaner for dry
materials.
SOL 3 / SOL 5 W / BDC 3122 / BDC 3140 / E-VAC3000

Wet vacuuming kit assembly

1
Cable
2
Cable
3
Control panel
4
Support
5
Control panel
Control panel replacement
Disconnect the cables (1) and (2) from the control
panel (3).
Disassemble the control panel (3).
Install the support (4) on the frame.
Install the control panel (5) on the support (4).
Connect the cables (1) and (2) to the control panel
(5).
1
Hole
2
Hole
Filtering chamber drilling
Drill holes (1) and (2) as shown in the figure.
1
Hole
2
Hole
3
Hose
4
Hose
5
Pressure switch
Hose connection
Install the supplied unions into the holes
(1): control panel side
(2): opposite side of control panel
Connect the hoses
(3): to the union installed into the hole (1) and to the
pressure switch (5)
(4): to the union installed into the hole (2) and to the
pressure switch (5) (electrical connection side).
Stop due to "container full"
When the liquid container is full, the vacuum cleaner
automatically stops. To start the vacuum cleaner again:
Empty the container.
Reinsert the container.
Turn the switch to "0" position, then to "1" position.
7
Figure 9
Figure 10
Figure 11