Descargar Imprimir esta página

Jocel JP2GV009081 Manual De Instrucciones página 28

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
• The gas ring burns unevenly
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 310mm
Depth: 510mm
Cut out dimensions
Width: 265mm
Depth: 480mm
TECHNICAL DATA
Burner's configuration
Rapid burner (medium)
Auxiliary burner (small)
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
NG I
(20)
2H
Injector Dia.
(mm)
1.11
2.7 (257.3 L/h)
0.72
1.0 (95.3 L/h)
-27-
CORRECTIVE ACTION
LPG I
kW
Injector
Dia.(mm)
0.83
0.52
(28~30/37)
3+
kW
2.7 (195.6 g/h)
1.0 (72.6 g(h)