Application
Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement
water heaters) is not possible.
Specifications
• Max. flow
- Spout
approx. 35 L/min or 9.2 gpm/60 psi
- Handshower
max. 9.3 L/min or 2.5 gpm/60 psi
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit with pressure reducing valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
Notes
• Installation of backflow protection must comply with local
codes and regulations.
• An access panel must be provided for access to diverting
unit and hose connections.
• Major pressure differences between cold and hot water
supply should be avoided.
Installation
Layout dimensions to establish centers and proper clearences,
see dimensional drawing on fold-out page I.
Fitting and connection, see fold-out page II and III, Figs. [1]
to [10].
The hot water supply should be connected on the left, the cold
water supply on the right side.
Water must flow in the direction of the arrows cast into the
body of the side valves and diverter.
Flush piping system prior and after installation of faucet
thoroughly!
Shut off cold and hot water supply.
I. Install side valves, see fold-out page II, Fig. [1].
II. Install spout, see Figs. [2] and [3].
III. Install diverter, see Fig. [4].
When screwing in (left-hand thread) the sleeve (A), make
sure that the internal groove aligns with the position of the
set screw (B).
IV.Install the hose guide and handshower, see Fig. [5].
V. Install hoses, see Figs. [6], [7] and [8].
Connection
Connect hoses (C) and (D) to the supply lines, see Fig. [9].
Open cold and hot water supply and check connections
for leakage.
VI.Install handles (E) and (F), see fold-out page III, Fig. [10].
1
English
Operation
- Handles (E) and (F), see fold-out page III, Fig. [11].
- Diverter (G)
Turning handles (E) and (F) releases the water supply.
Water will emerge from the bath inlet first.
Pull diverter knob
Press diverter knob
Flow is diverted automatically from shower outlet to bath inlet
when the faucet is closed.
7.25 psi
Maintenance
14.5 - 72.5 psi
Inspect and clean all parts, replace as necessary and lubricate
145 psi
with special grease.
232 psi
Shut off cold and hot water supply.
176 °F
I. Cartridge, see fold-out page III, Fig. [12].
Assemble in reverse order.
II. Spray hose and filter, see fold-out page III, Fig. [13].
Secure the spray hose against slipping down again.
Assemble in reverse order.
III.Diverter, see fold-out page III, Fig. [14].
Assemble in reverse order.
When screwing in (left-hand thread) the sleeve (A), make
sure that the internal groove aligns with the position of the
set screw (B).
IV.Flow control (13 922), see fold-out page I.
Assemble in reverse order.
Replacement parts, see fold-out page I (* = Special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
= flow is diverted from bath inlet
to shower outlet
= flow is diverted from shower
outlet to bath inlet