ELECTRICAL CONNECTIONS
To be certain that all of the air is out of the water heater, open the HOT
water faucet on your fixtures until constant water flows from them. If air
remains in the tank, the element will be damaged when connected to power.
Connect the water heater to a GROUNDED POWER SUPPLY.
The water heater is fitted with an electrical connection that is intended to connect
to a grounded 110-120 V/AC supply. Adhere to all pertinent State and local codes.
Install the correct size circuit breaker into the master panel. The Eemax Minitank
water heater was manufactured and wired in accordance with UL requirements.
The water heater is equipped with an overheat-limiting device with a manual
reset. Also known as the temperature high limit, this device has been factory
installed to interrupt the power supply in the event of a thermostat failure.
This water heater is designed for ONLY 110-120V electrical service!!!!! DO NOT
CONNECT TO HIGHER OR LOWER VOLTAGE.
Failure to use proper voltage may result in personal injury and/or property
damage. If the supplied electrical connection is either damaged or not long
enough, do NOT use an extension cord. Have a licensed electrician replace
.
the power cord