4.2
Testing the Socket
1.
Test the socket at the point of time you feel the lamp needs to
be switched on.
2.
Turn the SENS and LUX knobs fully clockwise; turn the TIME
knob fully anti-clockwise.
3.
Plug the socket into the mains. The socket needs a warm-up
time of ± 30 seconds before it will switch on the connected
lamp. When no signal is detected, the lamp will switch off after
± 10 seconds +/- 3 seconds.
4.
Turn the LUX knob fully anti-clockwise. The lamp should switch
off.
4.3
Setting the Socket
1.
Turn the SENS and LUX knobs until the lamp switches on.
2.
Now, set the switch-off delay with the TIME knob going from
± 10 seconds to ± 15 minutes.
V. 01 – 19/10/2018
E304-GN
4
©Velleman nv